Laboratory Equipment > Analytical Balances > Tenth of a Gram - 0.1 g | ||||||
|
||||||
OverviewThe occurrence of accidents, such as those that follow, whether expected or unexpected, can cause serious damage to your balance or problems with your measurements. The new A&D Apollo High Capacity, GX-M/GF-M series, is designed to provide excellent protection from these accidents, preventing loss due to downtime while also guaranteeing maximum productivity
|
The occurrence of accidents, such as those that follow, whether expected or unexpected, can cause serious damage to your balance or problems with your measurements. The new A&D Apollo High Capacity, GX-M/GF-M series, is designed to provide excellent protection from these accidents, preventing loss due to downtime while also guaranteeing maximum productivity.
Common accidents in weighing 1: Spillage
Common accidents in weighing 2: Impact shocks
Common accidents in weighing 3: Power failure
Common accidents in weighing 4: Misuse
Accuracy and precision management Automatic precision assessment (APA)
Automatic minimum weight calculation and implementation
Data output/communication
Universal Flexi Coms (UFC)
Gross/Net/Tare output
Special application function Flow rate display (FRD)
Options
Weighing of powder or liquid materials for filling, formulating, etc., always carries a risk of spillage, which could damage the balance.
IP65 dust and waterproof A&D Apollo High Capacity balances, which are IP65 rated, permit no ingress of dust, and can withstand water projected from any direction, as defined by the IEC/EN standard 60529.
The weight sensor of a high-precision balance will be damaged if continually affected by loads with acceleration (impact shocks). This typically occurs in factories where objects are placed roughly by machines or operators onto balances. In addition, impact shocks can easily shift values and cause errors.
Impact shock detection (ISD)
Impact-Alert
A&D Apollo High Capacity balances visualize the magnitude of impact shocks received by the weight sensor at four levels. Also, one beep is emitted if a Level 3 shock is received, and two beeps are emitted if a Level 4 shock is received (both of which should be avoided).
Shock-Log
While the power is on, up to 50 impacts of Level 3 and Level 4 will be stored in the balance with a timestamp (and log-in user information when the password lock function is used).
*1 This function is especially beneficial for quality managers, as it enables them to check and show how their balances were treated during use.
Cushioning mechanism
The two leaf springs that support the weighing pan mitigate impact shocks significantly
Power supply may be interrupted suddenly in the middle of measurement, spoiling your work.
Tare memory
When this function is activated, the tare value is saved in non-volatile memory, and the net value displayed before the power failure occurred is restored once the balance is turned on again. This also allows for the balance to be turned off during weigh-in or loss-in-weight measurement when necessary.
Auto power ON/OFF
The weighing mode display is automatically activated when AC power is supplied, so there is no need to press the ON/OFF key as the power comes back on, which is useful when the balance is part of an automated weighing system. Meanwhile, the balance can be set to switch off the display automatically after 10 minutes of inactivity to save power.
People may change the balance configuration or sensitivity without permission.
User access control (UAC) and key lock
A&D Apollo High Capacity balances can be password-protected in two ways: The first way is to limit use to authorized individuals (up to 11 including one administrator—the administrator can perform all operations while other users are limited to measurements and calibration*2 only) by setting a password for each user. The second way is to set a password for just the administrator, allowing anyone else to use the balance without entering a password, but for measurements and calibration*2 only.
Moreover, upon receiving a command to disable its keys, the balance becomes operable only by sending commands from an external device, such as a PC.
*2 The administrator can inhibit calibration also so that others can perform measurements
Automatic self calibration (ASC)*3
To ensure accuracy at all times, models with an internal weight (i.e. GX-M series) can be set to calibrate themselves automatically either (1) in response to change in ambient temperature to prevent error due to sensitivity drift, (2) at a set interval time, or (3) at predetermined (up to three) times of the day. Internal calibration can also be performed any time with one key press.
*3 Available for the GX-M series
In APA, the balance first makes quick diagnoses on whether there is a critical failure (Dia-Check), and then shows a repeatability test result (Standard Deviation) as well as the minimum weight (QuickMin-S) calculated using an electronically controlled load (ECL).*4 It only takes 1.5 minutes and can be readily included in a daily check SOP.
*4 ECL is A&Ds patented technology of generating a minute load (0.3 to 3% of the balance capacity) by purposely altering the equilibrium state of the electromagnetic force restoration sensor.
You can enter the minimum weight into the balance by either direct key input, using the result of QuickMin-S, or having the balance calculate it from 10 repeated measurements of an actual, external weight (the tolerance can be set to either 0.1% pursuant to USP Chapter 41, or 1%).
Further, to ensure that the measured sample amount meets the minimum weight requirement, the balance can display an alert until the sample amount reaches the value entered as the minimum weight (Min-S Alert).*5
*5 Only when g is selected as the unit of measure
RS-232C and USB interfaces as standard
The USB interface can be toggled between Quick USB mode (plug-and-play with weighing data output to a PC only) and Virtual COM mode (for bi-directional communication*6) using the internal settings. A USB cable (1.8 m) is provided as standard.
*6 For PCs with a Windows version other than Windows 10, a special driver downloaded from the A&D website needs to be installed
This function enables customization of printout content and layout by editing and sending commands to the balance (a dedicated software, WinCT-UFC, is available as a free download). Following the commands, the balance creates data to be output to either a printer capable of dump printing, such as the AD-8127 compact printer, or a commercially-available label printer*7 for barcode printing.
*7 A label printer that supports ZPL or ZPL II (ZPL and ZPL II are registered trademarks of ZIH Corp.)
Upon receiving a command, or with key operation, the balance can also output the gross, net, and tare values
FR-Cal
The balance can calculate and display/output the mass flow rate (the unit of measure can be selected from g/s, g/m or g/h), or the volume flow rate (mL/s, mL/m or mL/h) by entering the density of the material,*8 by itself. This function makes flow rate measurement much easier and more precise than manual calculation using a stopwatch. A dedicated graphing software, WinCT-FRD, is available as a free download.
*8 Up to 10 densities can be saved to the balance.
FR-Compare
The balance indicates whether the flow rate is maintained within the designated limits (either 3 levels or 5 levels). The results can be output using the optional GXM-04 interface.
GXM-04 *9*10 - Comparator relay output/buzzer/RS-232C/external key input interface
GXM-06 *9*10 - Analog (0-1/0.2-1 V) output/RS-232C interface
GXK-012 - Animal weighing pan
GXK-015 - Carrying case
GXM-27 *9*11 - Bluetooth® interface
Accessorie
With External Cal | GF-8202M | GF-8202MD | GF-10202M | GF-12001M | GF-22001M | GF-32001M | GF-32001MD |
---|---|---|---|---|---|---|---|
With Internal Cal | GX-8202M | GX-8202MD | GX-10202M | GX-12001M | GX-22001M | GX-32001M | GX-32001MD |
Capacity x Readability | 8.2 kg x 0.01 g | 2.2 kg x 0.01 g 8.2 kg x 0.1 g |
10.2 kg x 0.01 g | 12.2 kg x 0.1 g | 22.2 kg x 0.1 g | 32.2 kg x 0.1 g | 6.2 kg x 0.1 g 32.2 kg x 1 g |
Repeatability (standard deviation) | 0.01 g | 0.01 g / 0.05 g | 0.01 g | 0.1 g | 0.1 g | 0.1 g | 0.1 g / 0.5 g |
Linearity | ±0.03 g | ±0.02 g / ±0.1 g | ±0.03 g | ±0.2 g | ±0.2 g | ±0.2 g | ±0.2 g / ±1 g |
Stabilization time (typical when set to FAST) | Approx. 1.5 seconds | ||||||
Sensitivity drift (10 to 30 °C/50 to 86 °F, when automatic self calibration is OFF) | ±2 ppm/°C | ±3 ppm/°C | ±2 ppm/°C | ±3 ppm/°C | ±3 ppm/°C | ±3 ppm/°C | ±5 ppm/°C |
Accuracy immediately after internal ca libration (for the GX-M series)*ii | ±0.15 g | ±0.3 g | ±0.3 g | ±1.0 g | ±1.0 g | ±1.5 g | ±3 g |
Operating environment | 5 to 40 °C (41 to 104 °F), 85%RH or less (no condensation) | ||||||
Data memory | 200 weighing results + 50 calibration results (with timestamp), 50 unit masses for counting mode, 20 sets of upper/lower limit values for comparator mode, and 20 tare values | ||||||
Display refresh rate | 5 times/second, 10 times/second, or 20 times/second | ||||||
Units of measure | g (gram), kg (kilo gram), oz (ounce), lb (pound), lb-oz (pound-ounce), ozt (troy ounce), ct (metric carat), mom (momme), dwt (pennyweight), gr (grain), pcs (counting mode), % (percent mode), SG (density mode), and a user-programmable unit | ||||||
Counting mode: Minimum unit mass | 0.01 g | 0.1 g | 0.01 g | 0.1 g | 0.1 g | 0.1 g | 1 g |
Counting mode: Number of samples | 10, 25, 50 or 100 pieces | ||||||
Percent mode: Minimum 100% reference mass | 1 g | 10 g | 1 g | 10 g | 10 g | 10 g | 100 g |
Percent mode: % readability | 0.01%, 0.1% or 1% (depends on the reference mass stored) | ||||||
Communication interface | RS-232C and USB | ||||||
Applicable calibration weight value | 2 kg, 3 kg, 4 kg, 5 kg, 6 kg, 7 kg, 8 kg | 2 kg, 3 kg, 4 kg, 5 kg, 6 kg, 7 kg, 8 kg, 9 kg, 10 kg | 5 kg, 10 kg | 5 kg, 10 kg, 20 kg | 10 kg, 20 kg, 30 kg | ||
Weighing pan size | 270 x 210 mm | ||||||
External dimensions | 300 (W) x 355 (D) x 111 (H) mm | ||||||
Net weight | GX-M: Approx. 9.3 kg / GF-M: Approx. 8.3 kg | ||||||
Dust and waterproof rating | IP65 | ||||||
Power supply / consumption | AC adapter / approx. 30 VA | ||||||
Standard accessories | Display cover, AC adapter, USB cable (1.8 m), Simple breeze break (for the GX/F-8202M, GX/F-8202MD, and GX/F-10202M only) |
|