Laboratory Equipment > Analytical Balances > Analytical - 0.1 mg | ||||||
|
||||||
OverviewReceive the reliability and quality of a Sartorius balance, but just pay for the features you really need. The new Entris® has been specially designed to achieve effective and reliable weighing results in your daily work. The easy and clearly structured user interface, with its logical key assignment and last but not least the excellent readability, are ideal conditions for safe operation.
Capacity x Readability
Manufature:
Sartorius120 g x 0.1 mg Pan Size 90 mm (Diameter) SKU: ENTRIS124i-1S Weight: 8.00 lb |
Receive the reliability and quality of a Sartorius balance, but just pay for the features you really need. The new Entris® has been specially designed to achieve effective and reliable weighing results in your daily work. The easy and clearly structured user interface, with its logical key assignment and last but not least the excellent readability, are ideal conditions for safe operation.
Benefits
User-friendly Operation Excellent readability due to the backlit and high-contrast display, the easy navigation with function keys and the simple to read level indicator on the front enable an user-friendly and fast operation Basic Applications Entris® supports you in your daily work with integrated basic applications: animal weighing, density determination, counting, conversion or percentage. Easy Cleaning The side doors, top sliding door and easy to remove all stainless steel parts of the analytical draft shield chamber making it convenient for thorough cleaning. High Accuracy The monolithic weighing system ensures long-term high measurement accuracy and represents the proverbial reliability and quality of a Sartorius balance. Get the reliability and quality of a Sartorius balance, but only pay for the features you really need. The new Entris® has been specially designed to deliver effective and reliable weighing results in your daily work. The easy and clearly structured user interface, the logical key assignment and excellent readability are ideal features for error-free operation. Easy Cleaning The top and side sliding doors and easy-to-remove stainless steel parts of the draft shield chamber make Entris® convenient for thorough cleaning. High Accuracy The monolithic weigh cell ensures long-term high measurement accuracy and features the legendary reliability and quality of a Sartorius balance. Basic Applications Entris® supports you in your daily work with integrated basic applications: animal weighing, density determination, counting, conversion and weighing in percent. User-friendly Operation The backlit and high-contrast display ensures excellent readability. Easy navigation with function keys and the simple-to-read level indicator on the front enable userfriendly and fast operation. Applications: Weighing, Density, Percentage, Counting, Unstable Conditions, Conversion
Model
ENTRIS 124-1S
Capacity x Readability
120 x 0.0001 g
Repeatability (standard deviation)
0.1 mg
Linearity deviation
0.2 mg
Sensitivity drift between +10 °C and +30 °C
3 ± ppm/K
Typical stabilization time
2.5 s
Weighing pan size
90 mm dia
Weighing chamber height
173 + 176 + 240 mm
Net weight, approx.
4.4 kg
Calibration
External
Dimensions, D x W x H
230 x 303 x 330 mm
9.1 x 11.9 x 13 Inch
Levelling
Glass level indicator with air bubble for centering
Selectable weight units
Grams, Kilograms, Carats, Pounds, Ounces, Troy ounces, Hong Kong taels, Singapore taels, Taiwan taels, Grains, Pennyweights, Milligrams, Parts per pound, China taels, Mommes, Austrian carats, Tola, Baht, Mesghal, Tons, Pounds: ounces, Newton
Interface
RS232C 25-pin
Display
White backlit, high-contrast display with 15 mm digits
Standard built-in applications
Weighing, Density, Percentage, Counting, Animal Weighing, Conversion
Languages
English, French, German, Italian, Polish, Russian, Spanish
Anti-theft lock
Lockdown capability for cable or chain
Underfloor weighing
Integrated
Sartorius AC adaptor module
6971790 with interchangeable country-specific plug-in AC adaptors
Primary pover
100 – 240 V~, –10% | +10%, 50 – 60 Hz, 0.2 A
Secondary pover
15 V DC, ± 5%, 530 mA (max.) | 8 Watt (max.): 0 to +40 °C and
15 V DC, ± 5%, 330 mA (max.) | 5 Watt (max.): 0 to +50 °C
Other pover data
protection class II, in accordance with EN | IEC 60950-1 up to 3000 m above sea level; IP40 as per EN | IEC 60529
Power supply
only via Sartorius AC adaptor module 6971790
Input voltage
12.0 ... 18.0 V DC
Power consumption
2 W (typically)
Environment
for indoor use only
Ambient temperature
+10 °C to +30 °C
Operational capacity
guaranteed between +5 °C and +45 °C
Storage and shipping
–10 °C to +60 °C
Elevation
up to 3000 m above sea level
Relative humidity
15% to 80% for temperatures up to 31 °C; non-condensing, decreasing linearly to 50% relative humidity at 40 °C and 20% at 50 °C
Safety of electrical equipment
in accordance with EN 61010-1/IEC 61010-1 Safety requirements for electrical equipment for mea surement, control, and laboratory use – Part 1: General requirements
Electromagnetic compatibility
in accordance with EN 61326-1/IEC 61326-1 Electrical equipment for measurement, control, and laboratory use – EMC requirements - Part 1: General requirements
Interference emission
Class B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings). The device can therefore be used in both areas.
Model | ENTRIS 64i-1S |
ENTRIS 124i-1S |
ENTRIS 224i-1S |
ENTRIS 153i-1S |
ENTRIS 323i-1S |
ENTRIS 423i-1S |
ENTRIS 623i-1S |
ENTRIS 2202i-1S |
ENTRIS 3202i-1S |
ENTRIS 4202i-1S |
ENTRIS 6202i-1S |
ENTRIS 822i-1S |
ENTRIS 2201i-1S |
ENTRIS 5201i-1S |
ENTRIS 8201i-1S |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity x Readability | 60g x 0.1 mg | 120g x 0.1 mg | 220g x 0.1 mg | 150g x 1 mg | 320g x 1 mg | 420g x 1 mg | 620g x 1 mg | 2200g x 10 mg | 3200g x 10 mg | 4200g x 10 mg | 6200g x 10 mg | 820g x 10 mg | 2200g x 100 mg | 5200g x 100 mg | 8200g x 100 mg |
Repeatability (standard deviation) | 0.1 mg | 0.1 mg | 0.1 mg | 1 mg | 1 mg | 1 mg | 1 mg | 10 mg | 10 mg | 10 mg | 10 mg | 10 mg | 100 mg | 100 mg | 100 mg |
Linearity deviation | 0.2 mg | 0.2 mg | 0.2 mg | 2 mg | 2 mg | 2 mg | 2 mg | 30 mg | 30 mg | 30 mg | 30 mg | 30 mg | 300 mg | 300 mg | 300 mg |
Sensitivity drift between +10 °C and +30 °C | 3 ± ppm/K | 3 ± ppm/K | 3 ± ppm/K | 3 ± ppm/K | 3 ± ppm/K | 3 ± ppm/K | 3 ± ppm/K | 4 ± ppm/K | 4 ± ppm/K | 4 ± ppm/K | 4 ± ppm/K | 4 ± ppm/K | 8 ± ppm/K | 8 ± ppm/K | 8 ± ppm/K |
Typical stabilization time | 2.5 s | 2.5 s | 2.5 s | 1.3 s | 1.1 s | 1.0 s | 1.0 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s | 1.5 s |
Weighing pan size | 90 mm dia | 115 mm dia | 180 x 180 mm | 150 mm dia | 180 x 180 mm | ||||||||||
Weighing chamber height | 173 + 176 + 240 mm | - | |||||||||||||
Net weight, approx. | 4.4 kg | 2.6 kg | 3.2 kg | 3.1 kg | 2.0 kg | 2.7 kg | |||||||||
Calibration | External | ||||||||||||||
Dimensions, D x W x H | 230 x 303 x 330 mm | 230 x 303 x 136 mm | 230 x 303 x 91 mm | 230 x 303 x 87 mm | 230 x 303 x 91 mm | ||||||||||
9.1 x 11.9 x 13 Inch | 9.1 x 11.9 x 5.4 Inch | 9.1 x 11.9 x 3.6 Inch | 9.1 x 11.9 x 3.4 Inch | 9.1 x 11.9 x 3.6 Inch | |||||||||||
Levelling | Glass level indicator with air bubble for centering | ||||||||||||||
Selectable weight units | Grams, Kilograms, Carats, Pounds, Ounces, Troy ounces, Hong Kong taels, Singapore taels, Taiwan taels, Grains, Pennyweights, Milligrams, Parts per pound, China taels, Mommes, Austrian carats, Tola, Baht, Mesghal, Tons, Pounds: ounces, Newton | ||||||||||||||
Interface | RS232C 25-pin | ||||||||||||||
Display | White backlit, high-contrast display with 15 mm digits | ||||||||||||||
Standard built-in applications | Weighing, Density, Percentage, Counting, Animal Weighing, Conversion | ||||||||||||||
Languages | English, French, German, Italian, Polish, Russian, Spanish | ||||||||||||||
Anti-theft lock | Lockdown capability for cable or chain | ||||||||||||||
Underfloor weighing | Integrated | ||||||||||||||
Sartorius AC adaptor module | 6971790 with interchangeable country-specific plug-in AC adaptors | ||||||||||||||
Primary pover | 100 – 240 V~, –10% | +10%, 50 – 60 Hz, 0.2 A | ||||||||||||||
Secondary pover | 15 V DC, ± 5%, 530 mA (max.) | 8 Watt (max.): 0 to +40 °C and 15 V DC, ± 5%, 330 mA (max.) | 5 Watt (max.): 0 to +50 °C |
||||||||||||||
Other pover data | protection class II, in accordance with EN | IEC 60950-1 up to 3000 m above sea level; IP40 as per EN | IEC 60529 | ||||||||||||||
Power supply | only via Sartorius AC adaptor module 6971790 | ||||||||||||||
Input voltage | 12.0 ... 18.0 V DC | ||||||||||||||
Power consumption | 2 W (typically) | ||||||||||||||
Environment | for indoor use only | ||||||||||||||
Ambient temperature | +10 °C to +30 °C | ||||||||||||||
Operational capacity | guaranteed between +5 °C and +45 °C | ||||||||||||||
Storage and shipping | –10 °C to +60 °C | ||||||||||||||
Elevation | up to 3000 m above sea level | ||||||||||||||
Relative humidity | 15% to 80% for temperatures up to 31 °C; non-condensing, decreasing linearly to 50% relative humidity at 40 °C and 20% at 50 °C | ||||||||||||||
Safety of electrical equipment | in accordance with EN 61010-1/IEC 61010-1 Safety requirements for electrical equipment for mea surement, control, and laboratory use – Part 1: General requirements | ||||||||||||||
Electromagnetic compatibility | in accordance with EN 61326-1/IEC 61326-1 Electrical equipment for measurement, control, and laboratory use – EMC requirements - Part 1: General requirements | ||||||||||||||
Interference emission | Class B (suitable for use in residential areas and areas that are connected to a low voltage network that also supplies residential buildings). The device can therefore be used in both areas. |
|