| Mark 3 is a flexible moisture analyzer system for labs and production facilities. Its optional modular add-ons provide the best solution for every measuring task. more ... |
| Laboratory Equipment > Moisture Analyzers > Moisture Analyzers | ||||||
|
||||||
OverviewMark 3 is a flexible moisture analyzer system for labs and production facilities. Its optional modular add-ons provide the best solution for every measuring task.
|
||||||
Mark 3 is a flexible moisture analyzer system for labs and production facilities. Its optional modular add-ons provide the best solution for every measuring task.
Its high-resolution weighing system also makes the Mark 3 HP suitable for precisely analyzing the moisture and water content of very dry samples. This feature makes it a genuine alternative to Karl-Fisher titration.
With its resolution of 0.01%, the Mark 3 LTE has been optimized to achieve good reproducibility in routine measurements.Areas of Application:
Economical and reliable alternative to the drying oven
Equipment Supplied
Addition for Mark 3 LTE with printer:
| Model | LMA110-SET-P | LMA100-SET-P |
|---|---|---|
| Capacity x Readability | 40 x 0.001 g | 100 x 0.0001 g |
| Reproducibility | 1 mg | 0.1 mg |
| Calibration | External | Internal or External |
| Display of results | 0.01% | |
| Reproducibility of the measurement | Starting at an initial sample weight of approx. 1 g: ± 0.2% Starting at an initial sample weight of approx. 5 g: ± 0.05% |
|
| Method of measurement | Loss on Drying | |
| Recommended moisture range | 1.00–99.90% | |
| Heat source | Four parallel infrared quartz cylinders | |
| Modular configuration | Optional up to 4 heater modules connectable | |
| Internal printer | Optional internal thermal printer, 40 character graphic | |
| Temperature range and adjustment | 30–210°C in one-degree increments | |
| Temperature steps | Programmable, one or two | |
| Standby temperature | Standby temperature selectable from 30–160°C | |
| Temperature display | Display of target temperature and actual temperature during the measurement and in standby mode | |
| Measured value display | Weight loss in mg % moisture % dry weight % volatiles % moisture/dry weight |
|
| Modes of operation | Standard Test or Concentration mode | |
| Endpoint determination | Timer mode, value falls below a defined weight loss per time unit (%/min), trend shutoff | |
| Program storage | 60 programs, fail-safe storable | |
| Data storage | Storage 999 results with statistics: average, SD, RSD, high and low | |
| Temperature adjustment | Optional fixture for internal electronic two-point-adjustment | |
| Adjustment of the weighing system | External manual | |
| Ideal initial weight | Audio and visual display for programmable target sample weight addition | |
| Initial sample weight lock | Lockable initial sample weight for optimal repeatability | |
| Pass-Fail-function | Programmable target value including limiting values, pass-fail-information after the measurement | |
| Sample-ID | Numeric, numeric incrementing, alphanumeric or turned off | |
| User management | 20 users password protected storable | |
| Password protection | Password protection against undesired adjustment of parameters | |
| Languages | English, Spanish, German, French, Italian, Portuguese | |
| Date and time settings | dd|mm| yy, mm|dd| yy, 12 h- or 24 h-format | |
| Saving mode | Integrated clock timer to switch on and turn off the analyzer Programmable sleeping mode after a longer period of non-use | |
| Display | Illuminated VGA-display | |
| Parameter and data input | Sealed membrane witht audible tactile feedback | |
| Real-time curves | Real-time curves of the loss in weight (% or gram) as well of the temperature pattern during and after the measurement | |
| Acoustical signals | Key stroke, ideal weight met and end of test, selectable on or off | |
| System status indicator lights | Two tri-color LEDs (balance & heater) on front of heater module | |
| Data input|output | Serial and Ethernet | |
| Printout of the protocol | Internal thermal printer, 40 character graphic | |
| Printout format | Configurable printout: selectable header (3 lines), analyzer info, operator, Sample ID, calibration info, program name, program parameters, interval print, weight info, result and signature line | |
| Weighing system | Monolithic weighing system for high-precision results | |
| Balance spill protection | Reservoir under draft shield to collect liquids, powders or pellets | |
| Operating conditions | 15–40°C (59–104°F) | 10–85% rel. humidity, no condensation | |
| Power requirements | 90-250 VAC 50|60 Hz self-adjusting power supply | |
| Housing dimensions (W+D+H) | 41.3 x 49.5 x23.5 cm (164 x 191 x 94 in) modules combined | |
| Weight | 10 kg (22 lbs.) modules combined | |
| Warranty | 2 years | |
![]() MA100H-000115V1 Fully Automatic Infrared Moisture Analyzer with Halogen Heater 100 g x 0.1 mg $7,648.00 |
![]() LMA110-SET-P Infrared Moisture Analyzer with Printer 40 x 0.001 g $14,999.00 You are viewing this product |
![]() LMA200PM-000US Moisture Analyzer with built-in Printer 70 g x 0.1 mg $18,395.00 |