| The Sartorius H2O-I-2-TOC-T Arium® Comfort I TOC combines ASTM Type 1 ultrapure water and Type 3 reverse osmosis water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses two reverse osmosis modules to produce Type 3 water at 16 L/h and dispenses Type 1 ultrapure water at up to 2 L/min. This configuration includes an integrated 185/254 nm UV lamp to reduce organic contamination. more ... |
| Laboratory Equipment > Water Purification > Ultrapure Water Systems | ||||||
|
||||||
OverviewThe Sartorius H2O-I-2-TOC-T Arium® Comfort I TOC combines ASTM Type 1 ultrapure water and Type 3 reverse osmosis water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses two reverse osmosis modules to produce Type 3 water at 16 L/h and dispenses Type 1 ultrapure water at up to 2 L/min. This configuration includes an integrated 185/254 nm UV lamp to reduce organic contamination.
|
||||||
Sartorius H2O-I-2-TOC-T Arium® Comfort I TOC Benchtop Combined Laboratory Water Purification System with UV Lamp and TOC Monitor The Sartorius H2O-I-2-TOC-T Arium® Comfort I TOC combines ASTM Type 1 ultrapure water and Type 3 reverse osmosis water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses two reverse osmosis modules to produce Type 3 water at 16 L/h and dispenses Type 1 ultrapure water at up to 2 L/min. This configuration includes an integrated 185/254 nm UV lamp to reduce organic contamination. An integrated total organic carbon (TOC) monitor checks TOC readings at regular intervals and continuously displays the readings in real time. The purification process combines activated-carbon adsorption, reverse osmosis, ion exchange and UV oxidation. Pretreatment protects the RO membrane by removing oxidizing agents, including free chlorine and ozone, as well as heavy-metal ions and particulate contamination. The Comfort Kit uses semiconductor-quality mixed-bed ion-exchange resin and catalytic activated carbon to remove inorganic and organic constituents. Its top-down flow design promotes efficient contact with the purification media and prevents mixed-bed separation. Type 1 water reaches 18.2 MΩ·cm resistivity and 0.055 µS/cm conductivity at 25 °C. For this UV-equipped model, the specified TOC level is ≤2 ppb under the datasheet test conditions and depends on feed water quality. Type 3 RO water has typical conductivity below 20 µS/cm, typical resistivity above 0.05 MΩ·cm and typical ion retention up to 98%. Dissolved organic substances with molecular weight above 300 Daltons, particles and microorganisms are retained at rates greater than 99%. Performance depends on feed water quality and operating conditions. The integrated UV lamp operates at 185 and 254 nm to reduce organic impurities and help limit microbiological growth. Its horizontal arrangement reduces the temperature gradient associated with vertical placement, supporting consistent UV activity. The lamp is replaceable. Both UV treatment and the integrated TOC monitor are included in this model. The UV lamp reduces organic contamination, while the monitor measures and displays TOC readings to help assess organic purity during operation. Integrated iJust software uses calcium carbonate and carbon dioxide data to control a valve at the concentrate outlet. This adjusts water consumption and product-water quality to the incoming water conditions and helps extend the service life of downstream ultrapure-water cartridges. RO membrane backflushing with permeate helps remove accumulated particles and salts, supporting membrane life and consistent performance after periods of non-use. The touch-function display provides intuitive menu navigation and can be operated while wearing gloves. It also controls the dispensing valve. A Favorites function stores frequently used dispensing volumes for direct access. Volume-controlled dispensing covers 0.05–95 L with increments that vary by range; specified volume accuracy is 3% between 0.25 and 95 L under constant operating conditions. Large dispensing volumes depend on the available stored water and system capacity. Type 3 water is stored in a separate, closed Arium® Bagtank system. Replaceable bags protect the water from secondary contamination and eliminate the conventional reservoir cleaning procedure with chemicals. A ventilation filter with a non-return valve helps protect against carbon dioxide contamination. Bagtanks are offered in 20, 50 and 100 L capacities, with pumped and unpumped configurations. The system scope of supply does not list a Bagtank or bag; select these components separately for the required installation. The H2O-I-2-TOC-T is intended for benchtop installation. An optional H2O-ACK-D conversion kit allows a compatible benchtop unit to be installed under the bench with the display and dispenser mounted separately. The conversion kit includes extended tubing, cabling and a wall-mounting kit for the display/dispenser; conversion is to be performed by Sartorius Service specialists. Dedicated wall-mounted Comfort I models are also available. An SD card slot and RS-232 interface support data output. An optional printer can document current measurement values. The supplied Water Guard uses an optical leak sensor that functions independently of the very low conductivity of purified water. On detecting leakage, it shuts off the feed water inlet and provides audible and visual alarm indications. The two-module H2O-I-2-TOC-T provides the 16 L/h Type 3 production configuration with integrated UV treatment and TOC monitoring. Type 1 dispensing remains up to 2 L/min. Sartorius’s product page lists pre-treatment water consumption selection categories of 20–60 and 60–100 L/day and ultrapure-water consumption below 40 L/day; these are selection categories, not guaranteed production rates or measured feed-water use. H2O-I-2-TOC-T Features Applications and Configuration Selection The H2O-I-2-TOC-T provides the UV configuration identified in the datasheet for analytical applications, together with the routine laboratory uses listed for the series. The product page additionally lists life science applications, including DNA sequencing, endotoxin analysis, PCR and cell culture. Select the appropriate final filter for the required biological purity specifications. Optional Final Filters and Water Quality Accessories, Consumables and Expansion Arium® Bagtank Selection Arium® Comfort I Series: Full Model Comparison The following two tables include all 12 Comfort I order numbers in the supplied datasheet, split into six 8 L/h models and six 16 L/h models. T identifies benchtop installation and B identifies wall mounting. The 1 and 2 configurations provide 8 and 16 L/h Type 3 production respectively. UV versions include the UV lamp; TOC versions include both the UV lamp and TOC monitor. Shared specifications are repeated under each model to keep each model column complete.
| Specification | H2O-I-2-T | H2O-I-2-UV-T | H2O-I-2-TOC-T | H2O-I-2-B | H2O-I-2-UV-B | H2O-I-2-TOC-B |
|---|---|---|---|---|---|---|
| Manufacturer | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius |
| Series | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I |
| Installation | Benchtop | Benchtop | Benchtop | Wall-mounted | Wall-mounted | Wall-mounted |
| RO modules | 2 | 2 | 2 | 2 | 2 | 2 |
| Type 3 production output [1] | 16 L/h | 16 L/h | 16 L/h | 16 L/h | 16 L/h | 16 L/h |
| UV source | No | Yes; 185/254 nm | Yes; 185/254 nm | No | Yes; 185/254 nm | Yes; 185/254 nm |
| Integrated TOC monitor | No | No | Yes | No | No | Yes |
| Type 1 TOC [5] | <5 ppb | ≤2 ppb | ≤2 ppb | <5 ppb | ≤2 ppb | ≤2 ppb |
| Water types | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water |
| Type 1 purification | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions |
| Type 1 dispensing flow [1] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Type 1 conductivity [3] | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C |
| Type 1 resistivity [3] | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C |
| Volume-controlled dispensing | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps |
| Volume accuracy [2] | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L |
| Type 1 bacteria [6] | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus |
| Type 1 particles [6] | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus |
| Type 1 endotoxins [7] | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus |
| Type 1 RNase [7] | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus |
| Type 1 DNase [7] | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus |
| Type 3 purification | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis |
| Type 3 dispensing flow [4] | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank |
| Type 3 typical conductivity [8] | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm |
| Type 3 typical resistivity [8] | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical ion retention | Up to 98% | Up to 98% | Up to 98% | Up to 98% | Up to 98% | Up to 98% |
| Dissolved organics retention; MW >300 Da | >99% | >99% | >99% | >99% | >99% | >99% |
| Particle and microorganism retention | >99% | >99% | >99% | >99% | >99% | >99% |
| Type 1 daily use guidance | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day |
| Type 3 daily use guidance [9] | Approximately 200 L/day | Approximately 200 L/day | Approximately 200 L/day | Approximately 200 L/day | Approximately 200 L/day | Approximately 200 L/day |
| Feed water | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards |
| Feed water pressure [10] | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar |
| Feed water temperature | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C |
| Feed water conductivity | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C |
| Feed water TOC | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb |
| Maximum hardness as CaCO3 | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm |
| Free chlorine | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm |
| Total iron | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm |
| Silt density/fouling index | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 |
| Turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed water pH | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 |
| Dimensions (W x H x D) | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm |
| Empty weight | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg |
| Operating weight | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg |
| Power supply | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz |
| Maximum apparent power | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA |
| Ambient operating temperature | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH |
| Storage temperature | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH |
| Display | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation |
| Favorites | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes |
| Water optimization | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control |
| Data output | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 |
| Storage system | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L |
| Under-bench conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation |
| Optional remote ultrapure dispensing | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points |
| Smart Station flow [11] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Smart Station volume dispensing | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps |
| Smart Station particle/bacteria quality [6] | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus |
| Smart Station endotoxin/RNase/DNase quality [7] | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus |
| General laboratory applications | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry |
| Molecular biology application guidance | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses |
| Analytical application guidance | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis |
| Listed scope of supply | System, Water Guard, 2 RO modules, connection kit | System, Water Guard, 2 RO modules, connection kit; UV lamp | System, Water Guard, 2 RO modules, connection kit; UV lamp; TOC monitor | System, Water Guard, 2 RO modules, connection kit | System, Water Guard, 2 RO modules, connection kit; UV lamp | System, Water Guard, 2 RO modules, connection kit; UV lamp; TOC monitor |
| Specification | H2O-I-1-T | H2O-I-1-UV-T | H2O-I-1-TOC-T | H2O-I-1-B | H2O-I-1-UV-B | H2O-I-1-TOC-B |
|---|---|---|---|---|---|---|
| Manufacturer | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius |
| Series | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I | Arium® Comfort I |
| Installation | Benchtop | Benchtop | Benchtop | Wall-mounted | Wall-mounted | Wall-mounted |
| RO modules | 1 | 1 | 1 | 1 | 1 | 1 |
| Type 3 production output [1] | 8 L/h | 8 L/h | 8 L/h | 8 L/h | 8 L/h | 8 L/h |
| UV source | No | Yes; 185/254 nm | Yes; 185/254 nm | No | Yes; 185/254 nm | Yes; 185/254 nm |
| Integrated TOC monitor | No | No | Yes | No | No | Yes |
| Type 1 TOC [5] | <5 ppb | ≤2 ppb | ≤2 ppb | <5 ppb | ≤2 ppb | ≤2 ppb |
| Water types | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water | ASTM Type 1 ultrapure water and Type 3 RO water |
| Type 1 purification | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions |
| Type 1 dispensing flow [1] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Type 1 conductivity [3] | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C |
| Type 1 resistivity [3] | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C |
| Volume-controlled dispensing | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps |
| Volume accuracy [2] | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L |
| Type 1 bacteria [6] | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus |
| Type 1 particles [6] | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus |
| Type 1 endotoxins [7] | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus |
| Type 1 RNase [7] | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus |
| Type 1 DNase [7] | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus |
| Type 3 purification | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis | Activated-carbon adsorption, catalyst and reverse osmosis |
| Type 3 dispensing flow [4] | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank |
| Type 3 typical conductivity [8] | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm | <20 µS/cm |
| Type 3 typical resistivity [8] | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical ion retention | Up to 98% | Up to 98% | Up to 98% | Up to 98% | Up to 98% | Up to 98% |
| Dissolved organics retention; MW >300 Da | >99% | >99% | >99% | >99% | >99% | >99% |
| Particle and microorganism retention | >99% | >99% | >99% | >99% | >99% | >99% |
| Type 1 daily use guidance | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day |
| Type 3 daily use guidance [9] | Approximately 140 L/day | Approximately 140 L/day | Approximately 140 L/day | Approximately 140 L/day | Approximately 140 L/day | Approximately 140 L/day |
| Feed water | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards |
| Feed water pressure [10] | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar |
| Feed water temperature | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C |
| Feed water conductivity | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C |
| Feed water TOC | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb |
| Maximum hardness as CaCO3 | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm |
| Free chlorine | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm |
| Total iron | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm |
| Silt density/fouling index | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 |
| Turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed water pH | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 |
| Dimensions (W x H x D) | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm |
| Empty weight | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg | Approximately 23 kg |
| Operating weight | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg | Approximately 31 kg |
| Power supply | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz |
| Maximum apparent power | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA |
| Ambient operating temperature | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH |
| Storage temperature | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH |
| Display | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation | Touch-function display; glove-compatible operation |
| Favorites | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes |
| Water optimization | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control |
| Data output | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 |
| Storage system | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L |
| Under-bench conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation |
| Optional remote ultrapure dispensing | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points |
| Smart Station flow [11] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Smart Station volume dispensing | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps |
| Smart Station particle/bacteria quality [6] | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus |
| Smart Station endotoxin/RNase/DNase quality [7] | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus |
| General laboratory applications | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry |
| Molecular biology application guidance | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses | Datasheet lists standard Comfort I with Cell Plus final filter for the specified life science uses |
| Analytical application guidance | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis |
| Listed scope of supply | System, Water Guard, 1 RO module, connection kit | System, Water Guard, 1 RO module, connection kit; UV lamp | System, Water Guard, 1 RO module, connection kit; UV lamp; TOC monitor | System, Water Guard, 1 RO module, connection kit | System, Water Guard, 1 RO module, connection kit; UV lamp | System, Water Guard, 1 RO module, connection kit; UV lamp; TOC monitor |
Specification Conditions and Notes
| $13,062.80 |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||