| The Sartorius H2O-II-1-T Arium® Comfort II combines ASTM Type 1 ultrapure water and Type 2 pure water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses one reverse osmosis module to produce Type 2 water at 5 L/h and dispenses Type 1 ultrapure water at up to 2 L/min. more ... |
| Laboratory Equipment > Water Purification > Ultrapure Water Systems | ||||||
|
||||||
OverviewThe Sartorius H2O-II-1-T Arium® Comfort II combines ASTM Type 1 ultrapure water and Type 2 pure water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses one reverse osmosis module to produce Type 2 water at 5 L/h and dispenses Type 1 ultrapure water at up to 2 L/min.
|
||||||
Sartorius H2O-II-1-T Arium® Comfort II Benchtop Combined Laboratory Water Purification System The Sartorius H2O-II-1-T Arium® Comfort II combines ASTM Type 1 ultrapure water and Type 2 pure water production in a compact benchtop system. Connected directly to a suitable potable tap water supply, it uses one reverse osmosis module to produce Type 2 water at 5 L/h and dispenses Type 1 ultrapure water at up to 2 L/min. This configuration has neither a UV lamp nor an integrated total organic carbon (TOC) monitor. The purification process combines activated-carbon adsorption, reverse osmosis, softening, electrochemical deionization (EDI) and final ion exchange. EDI removes ions from the RO permeate to produce Type 2 pure water. A softener cartridge protects the EDI stage by removing traces of alkaline-earth ions. Pretreatment protects the RO membrane by removing oxidizing agents, including free chlorine and ozone, as well as heavy-metal ions and particulate contamination. The Comfort Kit uses semiconductor-quality mixed-bed ion-exchange resin and catalytic activated carbon to remove inorganic and organic constituents. Its top-down flow design promotes efficient contact with the purification media and prevents mixed-bed separation. Type 1 water reaches 18.2 MΩ·cm resistivity and 0.055 µS/cm conductivity at 25 °C. For this non-UV model, the specified TOC level is less than 5 ppb under the datasheet test conditions. Type 2 pure water has typical conductivity of 0.2–0.07 µS/cm and typical resistivity of 5–15 MΩ·cm, compensated to 25 °C. These values depend on feed water quality, dissolved carbon dioxide and temperature. Dissolved organic substances with molecular weight above 300 Daltons, particles and microorganisms are retained at rates greater than 99%; dissolved-organic retention also depends on the type of contamination. Performance depends on feed water quality and operating conditions. Integrated iJust software uses calcium carbonate and carbon dioxide data to control a valve at the concentrate outlet. This adjusts water consumption and product-water quality to the incoming water conditions and helps extend the service life of downstream ultrapure-water cartridges. RO membrane backflushing with permeate helps remove accumulated particles and salts, supporting membrane life and consistent performance after periods of non-use. The touch-function display provides intuitive menu navigation and can be operated while wearing gloves. It also controls the dispensing valve. A Favorites function stores frequently used dispensing volumes for direct access. Volume-controlled dispensing covers 0.05–95 L with increments that vary by range; specified volume accuracy is 3% between 0.25 and 95 L under constant operating conditions. Large dispensing volumes depend on the available stored water and system capacity. Type 2 water is stored in a separate, closed Arium® Bagtank system. Replaceable bags protect the water from secondary contamination and eliminate the conventional reservoir cleaning procedure with chemicals. A ventilation filter with a non-return valve helps protect against carbon dioxide contamination. Bagtanks are offered in 20, 50 and 100 L capacities, with pumped and unpumped configurations. The system scope of supply does not list a Bagtank or bag; select these components separately for the required installation. The H2O-II-1-T is intended for benchtop installation. An optional H2O-ACK-D conversion kit allows a compatible benchtop unit to be installed under the bench with the display and dispenser mounted separately. The kit includes extended tubing, cabling and display/dispenser wall mounting hardware; conversion is to be performed by Sartorius Service specialists. An SD card slot and RS-232 interface support data output. An optional printer can document current measurement values. The supplied Water Guard uses an optical leak sensor that functions independently of the very low conductivity of purified water. On detecting leakage, it shuts off the feed water inlet and provides audible and visual alarm indications. The one-module H2O-II-1-T provides 5 L/h Type 2 production using reverse osmosis and EDI treatment. Type 1 dispensing remains up to 2 L/min. Sartorius lists pre-treatment water consumption of 1–20 L/day and ultrapure-water consumption below 40 L/day as product selection categories; these are not guaranteed production rates or measured feed-water use. H2O-II-1-T Features Applications and Configuration Selection The datasheet identifies the standard Comfort II configuration for routine laboratory applications and the Comfort II UV configuration for the listed analytical applications. Select final filters and the UV configuration to suit the method and required water quality. The manufacturer’s broad series-level application list should not be treated as a statement that every model includes every necessary treatment option. Optional Final Filters and Water Quality Accessories, Consumables and Expansion Arium® Bagtank Selection Arium® Comfort II Series: Full Model Comparison The following two tables include all 12 Comfort II order numbers in the supplied datasheet, split into six 5 L/h models and six 10 L/h models. T identifies benchtop installation and B identifies wall mounting. The 1 and 2 configurations provide 5 and 10 L/h Type 2 production respectively. UV versions include the UV lamp; TOC versions include both the UV lamp and TOC monitor. Shared specifications are repeated under each model to keep each model column complete.
| Specification | H2O-II-1-T | H2O-II-1-UV-T | H2O-II-1-TOC-T | H2O-II-1-B | H2O-II-1-UV-B | H2O-II-1-TOC-B |
|---|---|---|---|---|---|---|
| Manufacturer | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius |
| Series | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II |
| Installation | Benchtop | Benchtop | Benchtop | Wall-mounted | Wall-mounted | Wall-mounted |
| RO modules | 1 | 1 | 1 | 1 | 1 | 1 |
| Type 2 production output [1] | 5 L/h | 5 L/h | 5 L/h | 5 L/h | 5 L/h | 5 L/h |
| UV source | No | Yes; 185/254 nm | Yes; 185/254 nm | No | Yes; 185/254 nm | Yes; 185/254 nm |
| Integrated TOC monitor | No | No | Yes | No | No | Yes |
| Type 1 TOC [5] | <5 ppb | ≤2 ppb | ≤2 ppb | <5 ppb | ≤2 ppb | ≤2 ppb |
| Water types | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water |
| Type 1 purification | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions |
| Type 1 dispensing flow [1] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Type 1 conductivity [3] | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C |
| Type 1 resistivity [3] | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C |
| Volume-controlled dispensing | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps |
| Volume accuracy [2] | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L |
| Type 1 bacteria [6] | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus |
| Type 1 particles [6] | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus |
| Type 1 endotoxins [7] | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus |
| Type 1 RNase [7] | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus |
| Type 1 DNase [7] | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus |
| EDI stage | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization |
| Type 2 purification | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization |
| Type 2 dispensing flow [4] | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank |
| Type 2 typical conductivity [8] | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C |
| Type 2 typical resistivity [8] | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C |
| RO membrane typical salt retention | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content |
| Dissolved organics retention; MW >300 Da | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type |
| Particle and microorganism retention | >99% | >99% | >99% | >99% | >99% | >99% |
| Type 1 daily use guidance | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day |
| Type 2 daily use guidance [9] | Approximately 120 L/day | Approximately 120 L/day | Approximately 120 L/day | Approximately 120 L/day | Approximately 120 L/day | Approximately 120 L/day |
| Feed water | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards |
| Feed water pressure [10] | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar |
| Feed water temperature | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C |
| Feed water conductivity | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C |
| Feed water TOC | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb |
| Maximum hardness as CaCO3 | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm |
| Free chlorine | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm |
| Total iron | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm |
| Feed water manganese | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm |
| Feed water aluminum | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm |
| Feed water dissolved CO2 | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm |
| Silt density/fouling index | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 |
| Turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed water pH | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 |
| Dimensions (W x H x D) | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm |
| Empty weight | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) |
| Operating weight | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) |
| Power supply | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz |
| Maximum apparent power | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA |
| Ambient operating temperature | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH |
| Storage temperature | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH |
| Display | Touch-function display | Touch-function display | Touch-function display | Touch-function display | Touch-function display | Touch-function display |
| Favorites | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes |
| Water optimization | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control |
| Data output | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 |
| Storage system | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L |
| Under-bench conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation |
| Optional remote ultrapure dispensing | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points |
| Smart Station flow [11] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Smart Station volume dispensing | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps |
| Smart Station particle/bacteria quality [6] | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus |
| Smart Station endotoxin/RNase/DNase quality [7] | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus |
| General laboratory applications | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry |
| Molecular biology application guidance | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography |
| Analytical application guidance | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis |
| Listed scope of supply | System, Water Guard, 1 RO module, connection kit | System, Water Guard, 1 RO module, connection kit; UV lamp | System, Water Guard, 1 RO module, connection kit; UV lamp; TOC monitor | System, Water Guard, 1 RO module, connection kit | System, Water Guard, 1 RO module, connection kit; UV lamp | System, Water Guard, 1 RO module, connection kit; UV lamp; TOC monitor |
| EDI softener cartridge | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 |
| High-flow RO replacement modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules |
| Specification | H2O-II-2-T | H2O-II-2-UV-T | H2O-II-2-TOC-T | H2O-II-2-B | H2O-II-2-UV-B | H2O-II-2-TOC-B |
|---|---|---|---|---|---|---|
| Manufacturer | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius | Sartorius |
| Series | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II | Arium® Comfort II |
| Installation | Benchtop | Benchtop | Benchtop | Wall-mounted | Wall-mounted | Wall-mounted |
| RO modules | 2 | 2 | 2 | 2 | 2 | 2 |
| Type 2 production output [1] | 10 L/h | 10 L/h | 10 L/h | 10 L/h | 10 L/h | 10 L/h |
| UV source | No | Yes; 185/254 nm | Yes; 185/254 nm | No | Yes; 185/254 nm | Yes; 185/254 nm |
| Integrated TOC monitor | No | No | Yes | No | No | Yes |
| Type 1 TOC [5] | <5 ppb | ≤2 ppb | ≤2 ppb | <5 ppb | ≤2 ppb | ≤2 ppb |
| Water types | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water | ASTM Type 1 ultrapure water and Type 2 pure water |
| Type 1 purification | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions | Activated-carbon adsorption and ion exchange; UV oxidation on UV/TOC versions |
| Type 1 dispensing flow [1] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Type 1 conductivity [3] | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C | 0.055 µS/cm at 25 °C |
| Type 1 resistivity [3] | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C | 18.2 MΩ·cm at 25 °C |
| Volume-controlled dispensing | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps | 0.05 L; 0.1-2.0 L in 0.1 L steps; 2.0-20 L in 1 L steps; 20-95 L in 5 L steps |
| Volume accuracy [2] | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L | 3% from 0.25-95 L |
| Type 1 bacteria [6] | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus | <0.001 CFU/mL with Sterile Plus |
| Type 1 particles [6] | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus | No particles >0.2 µm with Sterile Plus |
| Type 1 endotoxins [7] | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus | <0.001 EU/mL with Cell Plus |
| Type 1 RNase [7] | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus | <1 pg/mL with Cell Plus |
| Type 1 DNase [7] | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus | <5 pg/mL with Cell Plus |
| EDI stage | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization | Integrated electrochemical deionization |
| Type 2 purification | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization | Activated-carbon adsorption, catalyst, reverse osmosis, softening and electrochemical deionization |
| Type 2 dispensing flow [4] | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank | Up to 3 L/min with pumped Bagtank |
| Type 2 typical conductivity [8] | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C | 0.2–0.07 µS/cm at 25 °C |
| Type 2 typical resistivity [8] | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C | 5–15 MΩ·cm at 25 °C |
| RO membrane typical salt retention | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content | Up to 98%; RO module specification, not final Type 2 ion content |
| Dissolved organics retention; MW >300 Da | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type | >99%; depends on organic contamination type |
| Particle and microorganism retention | >99% | >99% | >99% | >99% | >99% | >99% |
| Type 1 daily use guidance | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day | Approximately 10-40 L/day |
| Type 2 daily use guidance [9] | Approximately 150 L/day | Approximately 150 L/day | Approximately 150 L/day | Approximately 150 L/day | Approximately 150 L/day | Approximately 150 L/day |
| Feed water | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards | Potable tap water meeting USA, EU or Japan drinking-water standards |
| Feed water pressure [10] | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar | 0.5-6.9 bar; recommended >2 bar |
| Feed water temperature | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C | 2-30 °C |
| Feed water conductivity | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C | <1,500 µS/cm; compensated to 25 °C |
| Feed water TOC | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb | <2,000 ppb |
| Maximum hardness as CaCO3 | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm | 360 ppm |
| Free chlorine | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm | <4 ppm |
| Total iron | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm | <0.1 ppm |
| Feed water manganese | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm |
| Feed water aluminum | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm | <0.05 ppm |
| Feed water dissolved CO2 | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm | ≤40 ppm |
| Silt density/fouling index | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 | SDI <5 |
| Turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed water pH | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 | 4-10 |
| Dimensions (W x H x D) | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm | 43.5 x 50.1 x 47.6 cm |
| Empty weight | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) | 28 kg (61.7 lb) |
| Operating weight | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) | 36 kg (79.4 lb) |
| Power supply | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz | 100-240 VAC (±10%); 50-60 Hz |
| Maximum apparent power | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA | 130 VA |
| Ambient operating temperature | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH | 2-35 °C; maximum 80% RH |
| Storage temperature | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH | 5-45 °C; maximum 80% RH |
| Display | Touch-function display | Touch-function display | Touch-function display | Touch-function display | Touch-function display | Touch-function display |
| Favorites | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes | Stored recurring dispensing volumes |
| Water optimization | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control | Integrated iJust control |
| Data output | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 | SD card slot and RS-232 |
| Storage system | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L | Separate closed Arium® Bagtank; 20, 50 or 100 L |
| Under-bench conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Optional H2O-ACK-D; Sartorius Service conversion | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation | Use comparable T model plus H2O-ACK-D for under-bench installation |
| Optional remote ultrapure dispensing | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points | Up to 3 Smart Station Ultrapure units; up to 4 total dispensing points |
| Smart Station flow [11] | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min | Up to 2 L/min |
| Smart Station volume dispensing | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps | 0.05-50 L in 50 mL steps |
| Smart Station particle/bacteria quality [6] | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus | No particles >0.2 µm; bacteria <0.001 CFU/mL with Sterile Plus |
| Smart Station endotoxin/RNase/DNase quality [7] | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus | <0.001 EU/mL; <1 pg/mL RNase; <5 pg/mL DNase with Cell Plus |
| General laboratory applications | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry | Buffers/media/pH solutions, histology, ELISA, AAS, GF-AAS, chemical analysis/synthesis, reagents and photometry |
| Molecular biology application guidance | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography | Datasheet lists standard Comfort II with Cell Plus for the specified life science uses, including chromatography |
| Analytical application guidance | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | Choose UV/TOC configuration for analytical applications listed in the datasheet | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis | UV configuration listed for SPE, trace metals, IC, ICP-MS, LC-MS, GC-MS, HPLC and TOC analysis |
| Listed scope of supply | System, Water Guard, 2 RO modules, connection kit | System, Water Guard, 2 RO modules, connection kit; UV lamp | System, Water Guard, 2 RO modules, connection kit; UV lamp; TOC monitor | System, Water Guard, 2 RO modules, connection kit | System, Water Guard, 2 RO modules, connection kit; UV lamp | System, Water Guard, 2 RO modules, connection kit; UV lamp; TOC monitor |
| EDI softener cartridge | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 | H2O-CSO-1 |
| High-flow RO replacement modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules | H2O-CRO-H-1: one module; H2O-CRO-H-2: two modules |
Specification Conditions and Notes
Specification Conditions and Notes
Manufacturer configuration note: the Comfort II datasheet ordering table lists H2O-II-2-B without a UV lamp or TOC monitor; the shop page simultaneously states UV Source: Yes and TOC <5 ppb. This description and comparison follow the model-specific datasheet ordering table. Confirm the supplied UV configuration with Sartorius when ordering.
| $16,883.06 |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||