| The Sartorius H2O-MUR-T Arium® Mini Essential Extend produces ASTM Type 1 ultrapure water from a directly connected pretreated-water line. Designed for laboratory demand below 10 L/day, this compact non-UV benchtop system accepts DI, RO or EDI supply water and provides direct access to dispensing functions through its color touchscreen. more ... |
| Laboratory Equipment > Water Purification > Ultrapure Water Systems | ||||||
|
||||||
OverviewThe Sartorius H2O-MUR-T Arium® Mini Essential Extend produces ASTM Type 1 ultrapure water from a directly connected pretreated-water line. Designed for laboratory demand below 10 L/day, this compact non-UV benchtop system accepts DI, RO or EDI supply water and provides direct access to dispensing functions through its color touchscreen.
|
||||||
Sartorius H2O-MUR-T Arium® Mini Essential Extend Benchtop Type 1 Ultrapure Water System The Sartorius H2O-MUR-T Arium® Mini Essential Extend produces ASTM Type 1 ultrapure water from a directly connected pretreated-water line. Designed for laboratory demand below 10 L/day, this compact non-UV benchtop system accepts DI, RO or EDI supply water and provides direct access to dispensing functions through its color touchscreen. Typical product-water resistivity is 18.2 MΩ·cm and conductivity is 0.055 µS/cm, compensated to 25 °C. The product page lists TOC below 10 ppb, no UV source and no integrated TOC monitor. The UV versions have separate, conditional TOC specifications. The Essential configuration draws from the laboratory’s pretreated-water supply without an integrated storage bag. Its Scientific Pack combines adsorption and ion exchange for final purification, with a separately selected final filter matched to the application. Manual dispensing, volume-controlled delivery and favorite-volume selections support routine sample and solution preparation. The touchscreen supports navigation with laboratory gloves. Dispensing is available from 50 mL to 5 L in 50 mL steps, at up to 1 L/min depending on pressure and final accessories. The flexible removable dispenser docks on a magnetic mount and participates in the water-circulation path. Manual delivery, numerical volume adjustment and recall of the last volume are accessible through the system display or handheld controls, making it easier to fill vessels of different shapes and sizes. H2O-MUR-T Features Applications Feed Water and Installation Requirements Consumables, Final Filters and Series Accessories Scope of Supply The datasheet lists one Arium Mini Essential Extend instrument with flexible dispensing unit, with UV supplied only for the UV configuration. Confirm the initial Scientific Pack and final-filter package for the exact order. No storage bag is needed for this direct-feed version.
| Specification | H2O-MM-T-US | H2O-MU-T-US | H2O-MUR-T | H2O-MA-T-US | H2O-MAR-T |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | No | No | No | No | No |
| TOC without UV | <10 ppb; exact US shop listing | Not stated | Not stated | Not stated | Not stated |
| Specification | H2O-MM-UV-T-US | H2O-MU-UV-T-US | H2O-MUR-UV-T-US | H2O-MA-UV-T-US | H2O-MAR-UV-T-US |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm |
| TOC with UV [7] | ≤5 ppb | ≤5 ppb | ≤5 ppb | <5 ppb | <5 ppb |
| Replacement UV lamp | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 |
Comparison Conditions and Source Notes
Service
Sartorius lists installation and commissioning, IQ/OQ qualification, and preventive maintenance including calibration, inspection, testing and consumable exchange.
| $6,490.32 |
|
||||||||||||||||||||||||