| The Sartorius H2O-MA-T-US Arium® Mini Plus connects directly to potable tap water and supplies both ASTM Type 1 ultrapure water and Type 3 reverse-osmosis water. It is designed for laboratories with ultrapure-water demand below 10 L/day. An integrated 5 L bag stores pretreated water for further purification. more ... |
| Laboratory Equipment > Water Purification > Ultrapure Water Systems | ||||||
|
||||||
OverviewThe Sartorius H2O-MA-T-US Arium® Mini Plus connects directly to potable tap water and supplies both ASTM Type 1 ultrapure water and Type 3 reverse-osmosis water. It is designed for laboratories with ultrapure-water demand below 10 L/day. An integrated 5 L bag stores pretreated water for further purification.
|
||||||
Sartorius H2O-MA-T-US Arium® Mini Plus Benchtop Type 1 Ultrapure / Type 3 RO Water System The Sartorius H2O-MA-T-US Arium® Mini Plus connects directly to potable tap water and supplies both ASTM Type 1 ultrapure water and Type 3 reverse-osmosis water. It is designed for laboratories with ultrapure-water demand below 10 L/day. An integrated 5 L bag stores pretreated water for further purification. Pretreatment combines spherical activated carbon, a catalyst and an RO membrane to reduce oxidants, heavy-metal ions, particles and salts. The RO stage produces up to 8 L/h of Type 3 water, depending on feed pressure, temperature and membrane condition. Adsorption, ion exchange and the selected final filter then support Type 1 purification. Typical Type 1 resistivity is 18.2 MΩ·cm and conductivity is 0.055 µS/cm at 25 °C. The product page lists TOC below 10 ppb for this non-UV US model. No UV source or integrated TOC monitor is specified. Type 3 conductivity is below 20 µS/cm and resistivity above 0.05 MΩ·cm, depending on feed water. The closed bag protects stored water against secondary contamination and limits ingress of ions and gases. Bag exchange simplifies maintenance and replaces conventional chemical reservoir cleaning. The Scientific Pack and final filters are selected to maintain the water quality required by the procedure. A glove-compatible color touchscreen provides manual, programmed-volume and favorite-volume dispensing. Type 1 delivery is up to 1 L/min, with 50 mL steps across 0.05–5 L. Type 3 water is dispensed pressure-free through a ball valve. Hourly RO production, instantaneous dispensing and bag capacity are separate ratings. H2O-MA-T-US Features and Performance Applications Feed Water and Installation Requirements Consumables, Final Filters and Series Accessories Scope of Supply The datasheet lists one Arium Mini Plus instrument, with UV supplied only for the UV configuration. Confirm the initial pretreatment cartridge, Scientific Pack, bag and final-filter package for the exact US order; the cited scope does not itemize these as included.
| Specification | H2O-MM-T-US | H2O-MU-T-US | H2O-MUR-T | H2O-MA-T-US | H2O-MAR-T |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | No | No | No | No | No |
| TOC without UV | <10 ppb; exact US shop listing | Not stated | Not stated | Not stated | Not stated |
| Specification | H2O-MM-UV-T-US | H2O-MU-UV-T-US | H2O-MUR-UV-T-US | H2O-MA-UV-T-US | H2O-MAR-UV-T-US |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm |
| TOC with UV [7] | ≤5 ppb | ≤5 ppb | ≤5 ppb | <5 ppb | <5 ppb |
| Replacement UV lamp | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 |
Comparison Conditions and Source Notes
Service
Sartorius lists installation and commissioning, IQ/OQ qualification, and preventive maintenance including calibration, inspection, testing and consumable exchange.
| $6,582.75 |
|
||||||||||||||||||||||||