| The Sartorius H2O-MM-T-US supplies ASTM Type 1 ultrapure water for small laboratory workflows with a daily requirement below 10 L. This non-UV benchtop model uses pretreated water supplied manually from a container, allowing operation without a permanent water-tap connection. Pretreated water is stored in an integrated 5 L bag before final purification. more ... |
| Laboratory Equipment > Water Purification > Ultrapure Water Systems | ||||||
|
||||||
OverviewThe Sartorius H2O-MM-T-US supplies ASTM Type 1 ultrapure water for small laboratory workflows with a daily requirement below 10 L. This non-UV benchtop model uses pretreated water supplied manually from a container, allowing operation without a permanent water-tap connection. Pretreated water is stored in an integrated 5 L bag before final purification.
|
||||||
Sartorius H2O-MM-T-US Arium® Mini Benchtop Type 1 Ultrapure Water System The Sartorius H2O-MM-T-US supplies ASTM Type 1 ultrapure water for small laboratory workflows with a daily requirement below 10 L. This non-UV benchtop model uses pretreated water supplied manually from a container, allowing operation without a permanent water-tap connection. Pretreated water is stored in an integrated 5 L bag before final purification. Typical product-water resistivity is 18.2 MΩ·cm and conductivity is 0.055 µS/cm, compensated to 25 °C. The product page lists TOC below 10 ppb for this exact model. It has no UV source or integrated TOC monitor. The lower TOC figures published for UV-equipped Mini configurations should be applied only to those versions and their stated feed-water conditions. The closed bag protects stored pretreated water from secondary contamination and limits ingress of ions and gases. Regular bag exchange helps prevent persistent biofilm and replaces the intensive chemical cleaning and rinsing associated with conventional storage tanks. A color touchscreen supports intuitive navigation while wearing laboratory gloves. Manual dispensing, volume-controlled dispensing and repeat-volume or favorite selections simplify routine preparation. The standard Mini delivers up to 1 L/min and dispenses 50 mL to 5 L in 50 mL steps. H2O-MM-T-US Features Applications Feed Water Requirements for H2O-MM-T-US Consumables and Accessories
| Specification | H2O-MM-T-US | H2O-MU-T-US | H2O-MUR-T | H2O-MA-T-US | H2O-MAR-T |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | No | No | No | No | No |
| TOC without UV | <10 ppb; exact US shop listing | Not stated | Not stated | Not stated | Not stated |
| Specification | H2O-MM-UV-T-US | H2O-MU-UV-T-US | H2O-MUR-UV-T-US | H2O-MA-UV-T-US | H2O-MAR-UV-T-US |
|---|---|---|---|---|---|
| Version | Mini | Mini Essential | Mini Essential Extend | Mini Plus | Mini Plus Extend |
| Installation | Benchtop | Benchtop | Benchtop | Benchtop | Benchtop |
| Feed arrangement | Manual pretreated-water container | Pretreated-water line | Pretreated-water line | Potable tap-water line | Potable tap-water line |
| Integrated Bagtank | 5 L integrated | None | None | 5 L integrated | 5 L integrated |
| Flexible removable Extend dispenser | No | No | Yes | No | Yes |
| Integrated tap-water pretreatment / RO | No | No | No | Yes | Yes |
| Ultrapure water type | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 | ASTM Type 1 |
| Typical resistivity at 25 °C | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm | 18.2 MΩ·cm |
| Typical conductivity at 25 °C | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm | 0.055 µS/cm |
| Maximum Type 1 delivery [1] | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min | Up to 1 L/min |
| Dispensing volume | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L | 0.05–5 L |
| Volume increments | 50 mL | 50 mL | 50 mL | 50 mL | 50 mL |
| Volume accuracy [2] | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±2%, 0.05–5 L | ±3%, 0.25–5 L | ±3%, 0.25–5 L |
| Bacteria with Sterile Plus [3] | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL | <0.001 CFU/mL |
| Particles with Sterile Plus [3] | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm | No particles >0.2 µm |
| Endotoxins with Cell Plus [4] | 0.001 EU/mL as printed; see note | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL | <0.001 EU/mL |
| RNase with Cell Plus [4] | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL | <1 pg/mL |
| DNase with Cell Plus [4] | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL | <5 pg/mL |
| Additional Type 3 water | Not specified | Not specified | Not specified | Available | Available |
| Type 3 production [5] | Not applicable | Not applicable | Not applicable | Up to 8 L/h | Up to 8 L/h |
| Type 3 delivery | Not applicable | Not applicable | Not applicable | Pressure-free via ball valve | Pressure-free via ball valve |
| Type 3 conductivity [5] | Not applicable | Not applicable | Not applicable | <20 µS/cm | <20 µS/cm |
| Type 3 resistivity [5] | Not applicable | Not applicable | Not applicable | >0.05 MΩ·cm | >0.05 MΩ·cm |
| Typical RO ion retention | Not applicable | Not applicable | Not applicable | Up to 98% | Up to 98% |
| RO dissolved-organic retention, MW >300 Da | Not applicable | Not applicable | Not applicable | >99% | >99% |
| RO particle / microorganism retention | Not applicable | Not applicable | Not applicable | >99% | >99% |
| Feed pressure | Pressure-free | 0–6.9 bar; recommended >2 bar | 0–6.9 bar; recommended >2 bar | 0–6 bar; recommended >2 bar | 0–6 bar; recommended >2 bar |
| Feed temperature | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C | 2–30 °C |
| Feed conductivity at 25 °C | <100 µS/cm | <100 µS/cm | <100 µS/cm | <1,500 µS/cm | <1,500 µS/cm |
| Feed TOC | <50 ppb | <50 ppb | <50 ppb | <2,000 ppb | <2,000 ppb |
| Feed turbidity | <1 NTU | <1 NTU | <1 NTU | <1 NTU | <1 NTU |
| Feed pH | 4–10 | 4–10 | 4–10 | 4–10 | 4–10 |
| Feed maximum hardness | Not listed | Not listed | Not listed | 360 ppm as CaCO3 | 360 ppm as CaCO3 |
| Feed free chlorine | Not listed | Not listed | Not listed | <4 ppm | <4 ppm |
| Feed total iron | Not listed | Not listed | Not listed | <0.1 ppm | <0.1 ppm |
| Feed SDI | Not listed | Not listed | Not listed | <10 | <10 |
| Dimensions W × H × D [6] | 280 × 510 × 530 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm | 280 × 510 × 530 mm | 370 × 640 × 610 mm |
| Approximate empty weight [6] | 13 kg | 13 kg | 14 kg | 13 kg | 14 kg |
| Approximate operating weight [6] | 23 kg | 23 kg | 24 kg | 23 kg | 24 kg |
| Power supply | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. | 100–240 VAC; 50/60 Hz; 2 A max. |
| Operating environment | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH | 2–35 °C; max. 80% RH |
| Storage environment | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH | 5–45 °C; max. 80% RH |
| Ultrapure cartridge | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK | H2O-S-PACK |
| Replacement storage bag | H2O-CBS-5-S | Not applicable | Not applicable | H2O-CBS-5-S | H2O-CBS-5-S |
| Tap-water pretreatment cartridge | Not applicable | Not applicable | Not applicable | H2O-CPR | H2O-CPR |
| Integrated UV | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm | 185/254 nm |
| TOC with UV [7] | ≤5 ppb | ≤5 ppb | ≤5 ppb | <5 ppb | <5 ppb |
| Replacement UV lamp | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 | H2O-CEL1 |
Comparison Conditions and Source Notes
Service
Sartorius lists installation and commissioning, IQ/OQ qualification, and preventive maintenance including calibration, inspection, testing and consumable exchange.
| $4,621.28 |
|
||||||||||||||||||||||||